top of page
itseries-site1.png

IT Series UPS Rack

GE IT Series UPS

GE's IT Series UPS delivers cost-effective power protection in both tower and 19-inch rack format. Equipped with AVR (Automatic Voltage Regulation), the range is ideal for server, data storage, networking and point of sale applications. The units are equipped with RS232 and USB communication ports as standard, and with an RJ11 port for telephone/modem protection.

The IT Series is a line interactive UPS with AVR (Automatic Voltage Regulation) ensuring a pure sine wave output and preventing damage due to power outages, voltage fluctuations and transient surges. All IT Series UPS have hot-swappable batteries and are provided with a two-year product warranty.

Features & Benefits

• High efficiency at all loads - Ideal for servers supporting varying load levels

• Advanced battery protection - Protection of the UPS core component

• Hot swappable batteries - Battery replacement without removing the load

• Regular automatic battery test - No surprises in the event of utility failure

• Short circuit and overload protection - UPS protection from external errors

• Cold start - UPS can start even without the utility present

Product Specifications

• Single Phase Output Voltages -125V

• 50/60 auto-sensing - Can be used as a frequency converter

• 95% efficiency - Low losses and greater energy savings

• Intelligent LED display - Quick visual of UPS, load and battery status

• Wide operating temperature - UPS can operate between 0°C to 40°C

Technical Specifications

MODEL NUMBER

POWER RATING

POWER FACTOR

INPUT

OUTPUT

PROTECTION & FILTERING

BATTERY

NET WEIGHT (lbs)
DIMENSIONS WxDxH (inches)

COMMUNICATIONS

 

 

 

ENVIRONMENT

CERTIFICATIONS

 

 

OUTPUT CAPACITY

OUTPUT POWER FACTOR

VOLTAGE
FREQUENCY
INPUT POWER CONNECTION

VOLTAGE (on battery)
VOLTAGE (on mains)
VOLTAGE THD
FREQUENCY (on battery)
VOLTAGE REGULATION (AVR)

 

 


OUTPUT RECEPTACLES - POWER DISTRIBUTION

SPIKE PROTECTION
EMI/RF FILTER
OVERLOAD PROTECTION
TRANSFER TIME
SHORT CIRCUIT

SYSTEM TYPE
BATTERY
TYPICAL RECHARGE TIME
PROTECTION
BATTERY QUANTITY

RS-232
USB
SNMP
OPERATING SYSTEM

AMBIENT OPERATION
AUDIBLE NOISE @ 1 METER
STORAGE CONDITION

UPS0600ITSIT , UPS1000ITSIT , UPS1500ITSIT , UPS2000ITSIT

600VA / 360W , 1000VA / 600W , 1500VA / 900W , 2000VA / 1200W

0.6 pf

120V +/- 10% at line input, single phase
50 or 60 Hz +/- 5Hz auto-sensing
Detachable 5-15P , Detachable 5-15P , Hardwired 5-15P , Hardwired 5-20P

Pure sine wave at +/- 5% of nominal, -10% of nominal after low battery warning
120V, -12%/+10%
< 5% @ 100% resistive load with 80% battery capacity
50 or 60 Hz +/- 5% auto-sensing
AVR automatically increases (boost) output voltage 17% above input voltage if -9% to -25% of nominal. AVR decreases (buck) output voltage 14% below input voltage if +9% to +25% of nominal.

(4) 5-15R , (4) 5-15R , (6) 5-15R , (6) 5-15R

 

780 Joules/6500A
10dB @ 0.15MHz, 50 dB @ 30 MHz
UPS automatic shutdown if overload exceeds 110% of nominal @ 20 seconds and 125% @ 5 seconds
4/6 milliseconds (typical), including detection time
Active protection with automatic shutdown

Hot swappable, sealed Valve Regulated Lead Acid (VRLA)
12V / 9.0 AH
4 hours (to 90% of full capacity)
Automatic self-test and discharge protection, Replace battery indicator
2 pcs , 2 pcs , 3 pcs , 4 pcs

30.4 lbs , 33.0 lbs , 55.0 lbs , 66.0 lbs
5.5" x 17.2" x 8.3" , 5.5" x 17.2" x 8.3" , 6.7" x 17.7" x 8.9" , 6.7" x 17.7" x 8.9"

Standard (Detect battery low, schedule UPS on/off, AC Input/Output power status display)
Standard
Optional
Windows NT, Windows 2000/ME, Windows XP, Linux

3,500 meters max. elevation, 0-95% RH non-condensing, 0-40°C
< 40 dBA , < 45 dBA
15,000 meters max. elevation, 0-95% RH non-condensing, 0-40°C

UL, cUL, FCC Class A