top of page
lp11useries-site1.png

LP11U Series Tower UPS

LP-11U Series UPS

The Digital Energy™ LP11U Series is a robust, high-performance UPS system that provides power protection for a wide range of mission critical applications. Every LP11U Series unit operates in a double conversion mode with true on-line VFI (voltage and frequency independent) operation, yielding maximum levels of power protection even under the toughest conditions. In addition, the LP11U Series UPS is easy to install and service, especially in an office environment. The robust design makes it suitable for traditional industrial applications as well.

To achieve redundancy or to increase power capacity, GE’s unique Redundant Parallel Architecture™ (RPA™) technology enables the LP11U Series to parallel up to four (4) units in a flexible and cost-effective manner. In the RPA™ system, every UPS is controlled in a true peer-to-peer configuration, with redundancy in all critical elements and functions. This advanced technology provides the highest possible system reliability for mission critical applications, eliminating any single points of failure associated with other types of UPS systems. The RPA™ system precisely synchronizes the output phase and automatically shares the load supported by each of the UPS.

Every GE UPS system is fully supported by GE’s Global Services team, providing world-class, 7x24 preventive and corrective services, training and application expertise.

Features & Benefits

 

Compact footprint and low noise - Easy to maneuver and install; suitable for installation even next to the user

• Isolation transformer design - Ensuring no DC on the output; ultimate site safety

• Matching battery cabinets - Extended runtime for all models

• Compliance to all safety and EMI standards - UL certified

• High reliability - >220,000 hours MTBF

• PDU options - Options to suit several output configurations

Product Specifications

• Single Phase Output Voltages - 120/208/230/240V


• Wide input voltage window - Minimizes battery use, prolongs battery life
 

• RPA functionality for paralleling and redundancy - UPS capacity can be increased as site requirements require at no extra cost
 

• Internal automatic bypass switch - Continuous power supply to the load even if the UPS is overloaded
 

• 0.8 output power factor - Prevents the need to oversize the UPS
 

• 0.99 input power factor
 

• Manual automatic bypass switch - Integrated as standard to the rear of the UPS
 

• GE's unique Superior Battery Management - Ultimate protection for the UPS core component
 

• High efficiency 91% - 94% (model dependent) - Using ECO mode, high efficiency and low losses
 

• No load shutdown - Prevents deep battery discharge al low loads
 

• Frequency conversion 50/60Hz - Operates as a frequency converter also operating in a parallel system

Technical Specifications

MODEL NUMBER

Rating (VA/W)

Backup Time @ 50% / 100% loads

Enclosure (Table 1)

Net Wgt Incl. Batteries (kg/lbs)

Input Voltage (VAC)

Nominal

Range @ 100% Load (V)

Range @ 50% Load (V)

Input Power Factor

Input Frequency (Hz)

Output Power Factor

Output Voltage (VAC) (sinusoidal)

Output Frequency (Hz)

Output Voltage Regulation

Output THD at Linear Load

Output THD at Non-linear Load

Crest Factor Handling Capacity of a Non-linear Load

Overload Capability on Inverter

Color

Environment

Operating Temperature / Humidity

Audible Noise

Safety Classifications & Listings

EMI

Surge Protection

Connectivity

Warranty

LP11U-5

LP11U-5 (120)

LP11U-6

LP11U-6 (120V)

LP11U-8

LP11U-10

5000 / 4000

25 / 10 min.

 

A

134/295

208

162-285

146-285

.99

40-70

.8

120+208+220/230/240 User Selectable

50/60

+/- 1%

<1%

<2%

5:1

110% 20 min., 130% 3.5 min., 150% 2 min.

Front bezel: Aluminum Grey (RAL9006); Cabinet: Pure White (RAL9010)

IP20 (IEC 60529)

32° F - 104° F (0° C - 40° C) / 95% Non-condensing

40-50 dBA - 3.3 feet (1 meter)

UL, cUL 1778; CE: EN50091-1-1; EN 60950; IEC 950

FCC Part 15 Class A / EN50091-2

IEC 1000-4-5 (6kV 1.2/50 μsec – 3kA 8/20 μsec) IEEE 587 B, EN 50091-2

RS-232; programmable alarm contacts (optional); SNMP (optional)

24 Months

5000 / 4000

25 / 10 min.

B

175/386

120

81-141

72-141

.99

40-70

.8

120+208+220/230/240 User Selectable

50/60

+/- 1%

<1%

<2%

5:1

110% 20 min., 130% 3.5 min., 150% 2 min.

Front bezel: Aluminum Grey (RAL9006); Cabinet: Pure White (RAL9010)

IP20 (IEC 60529)

32° F - 104° F (0° C - 40° C) / 95% Non-condensing

40-50 dBA - 3.3 feet (1 meter)

UL, cUL 1778; CE: EN50091-1-1; EN 60950; IEC 950

FCC Part 15 Class A / EN50091-2

IEC 1000-4-5 (6kV 1.2/50 μsec – 3kA 8/20 μsec) IEEE 587 B, EN 50091-2

RS-232; programmable alarm contacts (optional); SNMP (optional)

24 Months

6000 / 4800

20 / 8 min.

 

A

134/295

208

162-285

146-285

.99

40-70

.8

120+208+220/230/240 User Selectable

50/60

+/- 1%

<1%

<2%

5:1

110% 20 min., 130% 3.5 min., 150% 2 min.

Front bezel: Aluminum Grey (RAL9006); Cabinet: Pure White (RAL9010)

IP20 (IEC 60529)

32° F - 104° F (0° C - 40° C) / 95% Non-condensing

40-50 dBA - 3.3 feet (1 meter)

UL, cUL 1778; CE: EN50091-1-1; EN 60950; IEC 950

FCC Part 15 Class A / EN50091-2

IEC 1000-4-5 (6kV 1.2/50 μsec – 3kA 8/20 μsec) IEEE 587 B, EN 50091-2

RS-232; programmable alarm contacts (optional); SNMP (optional)

24 Months

6000 / 4800

 

20 / 8 min.

 

 

B

175/386

120

81-141
 

72-141

.99

40-70

.8

120+208+220/230/240 User Selectable

50/60

+/- 1%

<1%

<2%

5:1

110% 20 min., 130% 3.5 min., 150% 2 min.

Front bezel: Aluminum Grey (RAL9006); Cabinet: Pure White (RAL9010)

IP20 (IEC 60529)

32° F - 104° F (0° C - 40° C) / 95% Non-condensing

40-50 dBA - 3.3 feet (1 meter)

UL, cUL 1778; CE: EN50091-1-1; EN 60950; IEC 950

FCC Part 15 Class A / EN50091-2

IEC 1000-4-5 (6kV 1.2/50 μsec – 3kA 8/20 μsec) IEEE 587 B, EN 50091-2

RS-232; programmable alarm contacts (optional); SNMP (optional)

24 Months

8000 / 6400

29 / 11 min.

 

A

175/386

208

162-285

146-285

.99

40-70

.8

120+208+220/230/240 User Selectable

50/60

+/- 1%

<1%

<2%

5:1

110% 20 min., 130% 3.5 min., 150% 2 min.

Front bezel: Aluminum Grey (RAL9006); Cabinet: Pure White (RAL9010)

IP20 (IEC 60529)

32° F - 104° F (0° C - 40° C) / 95% Non-condensing

40-50 dBA - 3.3 feet (1 meter)

UL, cUL 1778; CE: EN50091-1-1; EN 60950; IEC 950

FCC Part 15 Class A / EN50091-2

IEC 1000-4-5 (6kV 1.2/50 μsec – 3kA 8/20 μsec) IEEE 587 B, EN 50091-2

RS-232; programmable alarm contacts (optional); SNMP (optional)

24 Months

10,000 / 8000

4500 / 3800

 

A

186/410

208

162-285

146-285

.99

40-70

.8

120+208+220/230/240 User Selectable

50/60

+/- 1%

<1%

<2%

5:1

110% 20 min., 130% 3.5 min., 150% 2 min.

Front bezel: Aluminum Grey (RAL9006); Cabinet: Pure White (RAL9010)

IP20 (IEC 60529)

32° F - 104° F (0° C - 40° C) / 95% Non-condensing

40-50 dBA - 3.3 feet (1 meter)

UL, cUL 1778; CE: EN50091-1-1; EN 60950; IEC 950

FCC Part 15 Class A / EN50091-2

IEC 1000-4-5 (6kV 1.2/50 μsec – 3kA 8/20 μsec) IEEE 587 B, EN 50091-2

RS-232; programmable alarm contacts (optional); SNMP (optional)

24 Months

1. Due to continuous product improvements, program specifications are subject to change without notice.

bottom of page